Ethylene Industry ›› 2018, Vol. 30 ›› Issue (3): 56-59.
• COMPRESSOR • Previous Articles Next Articles
Jiang Zezhou, Cheng Liang, Liu Houtao, Lu Weiguo
Received:
Accepted:
Online:
Published:
Abstract: The cracking gas compressor of an 800kt/a ethylene plant in China is large localized compressor unit with three cylinders and five stages, and is designed with three stages of backflow to one-stage suction, four stages of backflow to four-stage suction and five stages of backflow to five-stage suction to prevent the surge. In three years’ operation, there were problems including the operation safety margin of three-stage anti-surge system is low, the action of four-stage anti-surge valve easily leads to compressor trip, and the action of five-stage anti-surge valve easily leads to C2 front-end hydrogenation reactor trip. During the overhaul in 2016, the control system of the cracking gas compressor unit was optimized, the above-mentioned problems were solved successfully, the degree of automation was improved, energy saving and consumption reduction were achieved, and the operation of the compressor unit was stabilized.
Key words: ethylene plant}cracking gas compressor;anti-surge, optimization
Jiang Zezhou, Cheng Liang, Liu Houtao, Lu Weiguo. Optimization of Anti-Surge System of Cracking Gas Compressor[J].Ethylene Industry, 2018, 30(3): 56-59.