Ethylene Industry ›› 2025, Vol. 37 ›› Issue (2): 61-64.

• EQUIPMENT MAINTENANCE • Previous Articles    

Cause Analysis and Countermeasures against Freezing and Blocking of Cold Box Caused by Excessive Water Content at Outlet of Dryer in Ethylene Plant

Zhang Dianbo, Wang Mingchen, Zeng Mingyan,Jiang Tao, Jiang Liwei.    

  1. PetroChina Jilin Petrochemical Company, Jilin, Jilin, P.C.132021
  • Received:2024-04-09 Revised:2025-01-17 Online:2025-06-25 Published:2025-06-25
  • About author:张殿波,男,1990年毕业于吉林化工学校有机化工专业,本科,长期从事乙烯装置的生产运行管理工作,现为吉林石化公司炼化高级专家,高级工程师。

Abstract:

The cracking gas dryer of a 700 kt/a ethylene plant used 4.0 MPaG steam to heat the methane for dryer regeneration. During the operation of the vapor phase dryer, the excessive water content at the outlet of dryer led to production capacity constraints and the emergency shutdown of the plant. By analyzing the reasons for the excessive water content of the dryer, leaks in the heater were eliminated. The blockage locations were determined base on the change in pressure difference across equipment during operation. The ice build-up in equipment and pipelines was eliminated by taking some measures to defrost the cryogenic equipment frozen and blocked, and normal production was resumed.

Key words: dryer, excessive water content, measure