The pressure difference indicated by the differential gauge of ethylene distillation tower in the 1000 kt/a ethylene plant in Dushanzi exceeded the design operating value, and the feed load was reduced, restricting the increase of overall processing load of the ethylene plant. Through analysis, it was found that the reason for this problem was the plugging of tray caused by the entrance of green oil generated in C2 hydrogenation reactor. The plugging was removed successfully by injecting methanol into the proper position, and it was more effective to inject a large amount of methanol within a short period of time than injecting a small amount of methanol within a long period of time.
Key words:  , ethylene distillation tower;high pressure difference;green oil;methanol injection
Zhang Le, Wang Qiang, Wang Yaochen, Zhang Xiaolu, Li Zhaolong. Cause Analysis of High Pressure Difference of Ethylene Distillation Tower in Ethylene Plant and Its Solution[J].Ethylene Industry, 2020, 32(4): 25-27.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://yxgy.sei.com.cn/EN/
http://yxgy.sei.com.cn/EN/Y2020/V32/I4/25
Improvement Measures for Blocking of Debutanizer in the Ethylene Plant in Maoming
Analysis and Solution to Abnormal Pressure in Lubricating Oil System of Centrifugal Compressor
Discussion on Problems in Methanol Cleaning of Cold Box in Ethylene Plant
Comparative Analysis of Chemical Cleaning and Traditional Cleaning for Quench System
Application of New Polymerization Inhibitor in Pyrolysis Gasoline Extraction Unit
Cause Analysis and Measures against Frequent Leakage of Medium Pressure Condensate Line in DS Superheater
Problems in Hydrogenation of Raffinate C5 and the Countermeasures
Cited