Ethylene Industry ›› 2024, Vol. 36 ›› Issue (1): 42-44.

• COMPRESSOR • Previous Articles     Next Articles

Cause Analysis and Preventive Measures for Tube Bundle Leakage in Condenser of Cracking Gas Compressor

Shang Yongfu, Wang Chenyu, Li Wenting, Dai Chuan, Gao Wanfeng   

  1. PetroChina Dushanzi Petrochemical Company, Dushanzi, Xinjiang, P.C.833699
  • Received:2022-11-07 Revised:2023-11-14 Online:2024-03-25 Published:2024-03-28

Abstract:

The condenser of cracking gas compressor in ethylene plant is the accessory equipment of cracking gas compressor, and its leakage will affect the long-term operation of the ethylene plant. The causes of tube bundle leakage in the heat exchanger are analyzed, and some corresponding preventive measures are developed to extend the operation cycle of heat exchanger and reduce the probability of heat exchanger leakage during operation, thus ensuring the long-term operation of critical equipment in the ethylene plant.

Key words: condenser, leakage, control measure